DAIKIN / FAN COIL
Daikin FCU One way Cassette FXEQ-AV36
Compact one-way cassette with 3D airflow; some controller options are supplied separately.
Models and technical specifications ↓Discuss this series with AirHub360 ↗AIRHUB360 / SELECTION GUIDE
Where does this series fit?
A useful option when the ceiling layout calls for airflow from one side. Align the air path with the occupied area and avoid directing it onto a bed or desk. Check ceiling void, panel dimensions and drainage against the exact model before specifying it.
Plan around the actual space
Calculate each room’s heat load, considering sunlight, glazing, occupants, equipment and operating hours. Then check indoor/outdoor compatibility, pipe lengths and available electrical supply. Floor area or HP alone is not enough to select a system.
DAIKIN / MODEL DATA
Models and technical specifications
Values apply to the selected model. Indoor-unit power input is not total system input. Noise and airflow vary with operating settings. COP and seasonal efficiency are different measures; compare them only under equivalent test conditions.
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXEQ20AV36 |
| Cooling capacity | kW | 2.2 |
| Cooling capacity | BTU/hr | 7,500 |
| Power input | kW | 0.026 |
| Power supply | V/Ph/Hz | 1-phase, 220-240 V, 50 Hz |
| Airflow | m3/min | 6.0/5.4/4.9/4.4/4.0 |
| Airflow | cfm | 212/191/173/155/141 |
| Sound level | dB(A) | 30/29/28/27/26 |
| Unit dimensions H × W × D | mm | 200x840x470 |
| Panel dimensions H × W × D | mm | 80x950x550 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXEQ25AV36 |
| Cooling capacity | kW | 2.8 |
| Cooling capacity | BTU/hr | 9,600 |
| Power input | kW | 0.027 |
| Power supply | V/Ph/Hz | 1-phase, 220-240 V, 50 Hz |
| Airflow | m3/min | 6.9/6.4/5.8/5.3/4.8 |
| Airflow | cfm | 244/226/205/187/169 |
| Sound level | dB(A) | 32/31/30/29/28 |
| Unit dimensions H × W × D | mm | 200x840x470 |
| Panel dimensions H × W × D | mm | 80x950x550 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXEQ32AV36 |
| Cooling capacity | kW | 3.6 |
| Cooling capacity | BTU/hr | 12,300 |
| Power input | kW | 0.034 |
| Power supply | V/Ph/Hz | 1-phase, 220-240 V, 50 Hz |
| Airflow | m3/min | 8.0/7.5/7.0/6.3/5.5 |
| Airflow | cfm | 282/265/247/222/194 |
| Sound level | dB(A) | 35/34/33/32/30 |
| Unit dimensions H × W × D | mm | 200x840x470 |
| Panel dimensions H × W × D | mm | 80x950x550 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXEQ40AV36 |
| Cooling capacity | kW | 4.5 |
| Cooling capacity | BTU/hr | 15,400 |
| Power input | kW | 0.046 |
| Power supply | V/Ph/Hz | 1-phase, 220-240 V, 50 Hz |
| Airflow | m3/min | 9.8/8.8/7.8/7.0/6.2 |
| Airflow | cfm | 346/311/275/247/219 |
| Sound level | dB(A) | 38/37/35/33/31 |
| Unit dimensions H × W × D | mm | 200x840x470 |
| Panel dimensions H × W × D | mm | 80x950x550 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXEQ50AV36 |
| Cooling capacity | kW | 5.6 |
| Cooling capacity | BTU/hr | 19,100 |
| Power input | kW | 0.048 |
| Power supply | V/Ph/Hz | 1-phase, 220-240 V, 50 Hz |
| Airflow | m3/min | 12.5/11.4/10.4/9.5/8.7 |
| Airflow | cfm | 441/402/367/335/307 |
| Sound level | dB(A) | 38/37/35/33/31 |
| Unit dimensions H × W × D | mm | 200x1,240x470 |
| Panel dimensions H × W × D | mm | 80x1,350x550 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXEQ63AV36 |
| Cooling capacity | kW | 7.1 |
| Cooling capacity | BTU/hr | 24,200 |
| Power input | kW | 0.067 |
| Power supply | V/Ph/Hz | 1-phase, 220-240 V, 50 Hz |
| Airflow | m3/min | 15.0/13.6/12.2/11.0/9.8 |
| Airflow | cfm | 530/480/431/388/346 |
| Sound level | dB(A) | 43/41/39/37/35 |
| Unit dimensions H × W × D | mm | 200x1,240x470 |
| Panel dimensions H × W × D | mm | 80x1,350x550 |
Questions before choosing
Is FCU One way Cassette FXEQ-AV36 suitable for my space?
A useful option when the ceiling layout calls for airflow from one side. Align the air path with the occupied area and avoid directing it onto a bed or desk. Check ceiling void, panel dimensions and drainage against the exact model before specifying it.
How should I choose a model and cooling capacity?
Calculate each room’s heat load, considering sunlight, glazing, occupants, equipment and operating hours. Then check indoor/outdoor compatibility, pipe lengths and available electrical supply. Floor area or HP alone is not enough to select a system.
How can I request a quotation and installation assessment?
Share a floor plan or room dimensions, site photos, operating hours and installation constraints with AirHub360. The team can review model codes, controls and installation requirements. Pricing depends on the equipment schedule and site conditions.
AIRHUB360 / LET’S PLAN TOGETHER
Discuss this series with AirHub360
Tell us about your space so we can consider equipment, pipe routes, controls and long-term servicing together.