DAIKIN / FAN COIL
Daikin FCU Roundflow Cassette FXFQ-AVS
A cassette with 360-degree airflow; position it to suit the room layout and coverage requirements.
Models and technical specifications ↓Discuss this series with AirHub360 ↗AIRHUB360 / SELECTION GUIDE
Where does this series fit?
Consider a round-flow cassette for offices or shops with occupied areas around the room. Position the unit around ceiling beams and furniture so air reaches the occupied zone without a direct draught. Allow access to filters and the condensate system.
Plan around the actual space
Calculate each room’s heat load, considering sunlight, glazing, occupants, equipment and operating hours. Then check indoor/outdoor compatibility, pipe lengths and available electrical supply. Floor area or HP alone is not enough to select a system.
DAIKIN / MODEL DATA
Models and technical specifications
Values apply to the selected model. Indoor-unit power input is not total system input. Noise and airflow vary with operating settings. COP and seasonal efficiency are different measures; compare them only under equivalent test conditions.
| Specification | Unit | Manufacturer data |
|---|---|---|
| Indoor model | — | FXFQ140AVS |
| Cooling capacity | kW | 16 |
| Cooling capacity | BTU/hr | 54,600 |
| Power input | kW | 0.203 |
| Power supply | V/Ph/Hz | 1-phase, 220 V, 50 Hz |
| Airflow | m3/min | 35.5 / 32.5 / 29.5 / 26.5 / 23 |
| Airflow | cfm | 1,253 / 1,147 / 1,041 / 935 / 812 |
| Sound level | dB(A) | 46 / 43.5 / 40.5 / 38 / 35 |
| Unit dimensions H × W × D | mm | 298×840×840 |
Questions before choosing
Is FCU Roundflow Cassette FXFQ-AVS suitable for my space?
Consider a round-flow cassette for offices or shops with occupied areas around the room. Position the unit around ceiling beams and furniture so air reaches the occupied zone without a direct draught. Allow access to filters and the condensate system.
How should I choose a model and cooling capacity?
Calculate each room’s heat load, considering sunlight, glazing, occupants, equipment and operating hours. Then check indoor/outdoor compatibility, pipe lengths and available electrical supply. Floor area or HP alone is not enough to select a system.
How can I request a quotation and installation assessment?
Share a floor plan or room dimensions, site photos, operating hours and installation constraints with AirHub360. The team can review model codes, controls and installation requirements. Pricing depends on the equipment schedule and site conditions.
AIRHUB360 / LET’S PLAN TOGETHER
Discuss this series with AirHub360
Tell us about your space so we can consider equipment, pipe routes, controls and long-term servicing together.