DAIKIN / CONDENSING UNIT
Daikin VRV IV Q Series
A replacement-focused series that can reuse existing refrigerant pipes when manufacturer conditions are met.
Models and technical specifications ↓Discuss this series with AirHub360 ↗AIRHUB360 / SELECTION GUIDE
Where does this series fit?
A starting point for replacing an existing building system where reusing eligible refrigerant pipework may reduce disruption. Reuse is conditional: pipe material, dimensions, condition and manufacturer requirements must be checked. Survey the existing installation before estimating savings or downtime.
Plan around the actual space
Calculate each room’s heat load, considering sunlight, glazing, occupants, equipment and operating hours. Then check indoor/outdoor compatibility, pipe lengths and available electrical supply. Floor area or HP alone is not enough to select a system.
DAIKIN / MODEL DATA
Models and technical specifications
Values apply to the selected model. Indoor-unit power input is not total system input. Noise and airflow vary with operating settings. COP and seasonal efficiency are different measures; compare them only under equivalent test conditions.
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ6TY1S (Standard Type) |
| Cooling capacity | kW | 16 |
| Power input | kW | 3.63 |
| COP | W/W | 4.41 |
| Unit dimensions H × W × D | mm | 1,657X930X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ8TY1S (Standard Type) |
| Cooling capacity | kW | 22.4 |
| Power input | kW | 5.18 |
| COP | W/W | 4.32 |
| Unit dimensions H × W × D | mm | 1,657X930X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ10TY1S (Standard Type) |
| Cooling capacity | kW | 28 |
| Power input | kW | 6.88 |
| COP | W/W | 4.07 |
| Unit dimensions H × W × D | mm | 1,657X930X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ12TY1S (Standard Type) |
| Cooling capacity | kW | 33.5 |
| Power input | kW | 8.82 |
| COP | W/W | 3.8 |
| Unit dimensions H × W × D | mm | 1,657X930X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ14TY1S (Standard Type) |
| Cooling capacity | kW | 40 |
| Power input | kW | 10.7 |
| COP | W/W | 3.74 |
| Unit dimensions H × W × D | mm | 1,657X1,240X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ16TY1S (Standard Type) |
| Cooling capacity | kW | 45 |
| Power input | kW | 13 |
| COP | W/W | 3.46 |
| Unit dimensions H × W × D | mm | 1,657X1,240X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ18TNY1S (Standard Type) |
| Unit combination | — | RQQ8TY1SRQQ10TY1S |
| Cooling capacity | kW | 50.40 |
| Power input | kW | 12 |
| COP | W/W | 4.2 |
| Unit dimensions H × W × D | mm | 2x(1,657X930X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ20TNY1S (Standard Type) |
| Unit combination | — | RQQ8TY1SRQQ12TY1S |
| Cooling capacity | kW | 55.9 |
| Power input | kW | 14 |
| COP | W/W | 3.99 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 930 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ22TNY1S (Standard Type) |
| Unit combination | — | RQQ10TY1SRQQ12TY1S |
| Cooling capacity | kW | 61.5 |
| Power input | kW | 15.7 |
| COP | W/W | 3.92 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 930 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ24TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ12TY1S |
| Cooling capacity | kW | 67 |
| Power input | kW | 17.6 |
| COP | W/W | 3.81 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 930 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ26TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ14TY1S |
| Cooling capacity | kW | 73.5 |
| Power input | kW | 19.5 |
| COP | W/W | 3.77 |
| Unit dimensions H × W × D | mm | (1,657X930X765)+ (1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ28TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ16TY1S |
| Cooling capacity | kW | 78.5 |
| Power input | kW | 21.8 |
| COP | W/W | 3.6 |
| Unit dimensions H × W × D | mm | (1,657 x 930 x 765)+(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ30TNY1S (Standard Type) |
| Unit combination | — | RQQ14TY1SRQQ16TY1S |
| Cooling capacity | kW | 85 |
| Power input | kW | 23.7 |
| COP | W/W | 3.59 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ32TNY1S (Standard Type) |
| Unit combination | — | RQQ14TY1SRQQ18TY1S |
| Cooling capacity | kW | 90 |
| Power input | kW | 26 |
| COP | W/W | 3.46 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ34TNY1S (Standard Type) |
| Unit combination | — | RQQ10TY1SRQQ12TY1SRQQ12TY1S |
| Cooling capacity | kW | 95 |
| Power input | kW | 24.5 |
| COP | W/W | 3.88 |
| Unit dimensions H × W × D | mm | 3x(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ36TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ12TY1SRQQ12TY1S |
| Cooling capacity | kW | 101 |
| Power input | kW | 26.5 |
| COP | W/W | 3.81 |
| Unit dimensions H × W × D | mm | 3x(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ38TNY1S (Standard Type) |
| Unit combination | — | RQQ8TY1SRQQ12TY1SRQQ18TY1S |
| Cooling capacity | kW | 106 |
| Power input | kW | 29.4 |
| COP | W/W | 3.61 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 930 x 765)+(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ40TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ12TY1SRQQ16TY1S |
| Cooling capacity | kW | 112 |
| Power input | kW | 30.6 |
| COP | W/W | 3.66 |
| Unit dimensions H × W × D | mm | 2x(1,657 x 930 x 765)+(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ42TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ14TY1SRQQ16TY1S |
| Cooling capacity | kW | 119 |
| Power input | kW | 32.5 |
| COP | W/W | 3.66 |
| Unit dimensions H × W × D | mm | (1,657 x 930 x 765)+2(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ44TNY1S (Standard Type) |
| Unit combination | — | RQQ12TY1SRQQ16TY1SRQQ16TY1S |
| Cooling capacity | kW | 124 |
| Power input | kW | 34.8 |
| COP | W/W | 3.56 |
| Unit dimensions H × W × D | mm | (1,657 x 930 x 765)+2(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ46TNY1S (Standard Type) |
| Unit combination | — | RQQ14TY1SRQQ14TY1SRQQ18TY1S |
| Cooling capacity | kW | 130 |
| Power input | kW | 36.8 |
| COP | W/W | 3.53 |
| Unit dimensions H × W × D | mm | 3x(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ48TNY1S (Standard Type) |
| Unit combination | — | RQQ14TY1SRQQ16TY1SRQQ18TY1S |
| Cooling capacity | kW | 135 |
| Power input | kW | 39.1 |
| COP | W/W | 3.45 |
| Unit dimensions H × W × D | mm | 3x(1,657 x 1,240 x 765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ18TY1S (Space Saving Type) |
| Cooling capacity | kW | 50 |
| Power input | kW | 15.4 |
| COP | W/W | 3.25 |
| Unit dimensions H × W × D | mm | 1,657X1,240X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ20TY1S (Space Saving Type) |
| Cooling capacity | kW | 56 |
| Power input | kW | 18 |
| COP | W/W | 3.11 |
| Unit dimensions H × W × D | mm | 1,657X1,240X765 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ30TSY1S (Space Saving Type) |
| Unit combination | — | RQQ12TY1SRQQ18TY1S |
| Cooling capacity | kW | 83.5 |
| Power input | kW | 24.2 |
| COP | W/W | 3.45 |
| Unit dimensions H × W × D | mm | (1,657X930X765)+ (1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ32TSY1S (Space Saving Type) |
| Unit combination | — | RQQ12TY1SRQQ20TY1S |
| Cooling capacity | kW | 89.5 |
| Power input | kW | 26.8 |
| COP | W/W | 3.34 |
| Unit dimensions H × W × D | mm | (1,657X930X765)+ (1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ34TSY1S (Space Saving Type) |
| Unit combination | — | RQQ16TY1SRQQ18TY1S |
| Cooling capacity | kW | 95 |
| Power input | kW | 28.4 |
| COP | W/W | 3.35 |
| Unit dimensions H × W × D | mm | 2x(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ36TSY1S (Space Saving Type) |
| Unit combination | — | RQQ18TY1SRQQ18TY1S |
| Cooling capacity | kW | 100 |
| Power input | kW | 30.8 |
| COP | W/W | 3.25 |
| Unit dimensions H × W × D | mm | 2x(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ38TSY1S (Space Saving Type) |
| Unit combination | — | RQQ18TY1SRQQ20TY1S |
| Cooling capacity | kW | 106 |
| Power input | kW | 33.4 |
| COP | W/W | 3.17 |
| Unit dimensions H × W × D | mm | 2x(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ40TSY1S (Space Saving Type) |
| Unit combination | — | RQQ20TY1SRQQ20TY1S |
| Cooling capacity | kW | 112 |
| Power input | kW | 36 |
| COP | W/W | 3.11 |
| Unit dimensions H × W × D | mm | 2x(1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ42TSY1S (Space Saving Type) |
| Unit combination | — | RQQ12TY1SRQQ12TY1SRQQ18TY1S |
| Cooling capacity | kW | 117 |
| Power input | kW | 33 |
| COP | W/W | 3.55 |
| Unit dimensions H × W × D | mm | 2x (1,657X930X765)+ (1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ44TSY1S (Space Saving Type) |
| Unit combination | — | RQQ12TY1SRQQ12TY1SRQQ20TY1S |
| Cooling capacity | kW | 123 |
| Power input | kW | 35.6 |
| COP | W/W | 3.46 |
| Unit dimensions H × W × D | mm | 2X(1,657X930X765)+ (1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ46TSY1S (Space Saving Type) |
| Unit combination | — | RQQ12TY1SRQQ16TY1SRQQ18TY1S |
| Cooling capacity | kW | 129 |
| Power input | kW | 37.2 |
| COP | W/W | 3.47 |
| Unit dimensions H × W × D | mm | (1,657X930X765)+ 2x (1,657X1,240X765) |
| Specification | Unit | Manufacturer data |
|---|---|---|
| Outdoor model | — | RQQ48TSY1S (Space Saving Type) |
| Unit combination | — | RQQ12TY1SRQQ18TY1SRQQ18TY1S |
| Cooling capacity | kW | 134 |
| Power input | kW | 39.6 |
| COP | W/W | 3.38 |
| Unit dimensions H × W × D | mm | (1,657X930X765)+ 2x (1,657X1,240X765) |
Questions before choosing
Is VRV IV Q Series suitable for my space?
A starting point for replacing an existing building system where reusing eligible refrigerant pipework may reduce disruption. Reuse is conditional: pipe material, dimensions, condition and manufacturer requirements must be checked. Survey the existing installation before estimating savings or downtime.
How should I choose a model and cooling capacity?
Calculate each room’s heat load, considering sunlight, glazing, occupants, equipment and operating hours. Then check indoor/outdoor compatibility, pipe lengths and available electrical supply. Floor area or HP alone is not enough to select a system.
How can I request a quotation and installation assessment?
Share a floor plan or room dimensions, site photos, operating hours and installation constraints with AirHub360. The team can review model codes, controls and installation requirements. Pricing depends on the equipment schedule and site conditions.
AIRHUB360 / LET’S PLAN TOGETHER
Discuss this series with AirHub360
Tell us about your space so we can consider equipment, pipe routes, controls and long-term servicing together.