Middle Static Duct Inverter FBA-CV2S
Daikin FBA-CV2S is a medium-static inverter ducted series for concealed installation and air outlets coordinated with the interior.

DAIKIN / SKY AIR
Daikin FDLF-EV2S is a low-static inverter ducted series with a 200 mm body height, for ceiling voids shared with other building services.
Models and technical specifications ↓Discuss this series ↗Set the finished ceiling level only after allowing for insulation, drainage and hangers. Keep duct resistance compatible with the low-static design and preserve service openings.
DAIKIN / MODEL DATA
Select a code to view its specifications, and confirm the indoor/outdoor pairing before using the data for design.
| Specification | Unit | Manufacturer data |
|---|---|---|
| System data | ||
| Cooling capacity | kW | 3.8/(1.8~4.5) |
| Seasonal energy efficiency ratio (SEER) | BTU/W.h | 17.07 |
| Power supply | V/Ph/Hz | Supply from Outdoor and Indoor(Indoor) EV2S: 220V / 1 Phase / 50Hz(Outdoor) EV2S: 220V / 1 Phase / 50Hz |
| System model combination | — | FDLF13EV2S/RZFC13EV2S |
| Power input | W | 1,120 |
| Cooling capacity | BTU/hr | 13,000/(6100~15400) |
| Indoor unit | ||
| Airflow rate | cfm | 565 / 494 / 423 |
| Fan speed settings | — | 3Step |
| Air filter | — | Removable/Washable/Mildew proof |
| Sound level | dB(A) | 37 / 33 / 30 |
| Dimensions (H × W × D) | mm | 200 x 900 x 620 |
| Weight | kg | 28 |
| Indoor unit model | — | FDLF13EV2S |
| External static pressure | Pa | Rated 15/(15-38) |
| Drain connection size | mm | VP25 (I.D.∅25 x O.D.∅34) |
| Airflow rate | m3/min | 16/14/12 |
| Outdoor unit | ||
| Dimensions (H × W × D) | mm | 595x845x300 |
| Weight | kg | 34 |
| Compressor type | — | Hermetically sealed swing type |
| Refrigerant | — | R32 |
| Piping length without additional refrigerant | m | 15 |
| Maximum piping length | m | 30 (equivalent length 40 m) |
| Maximum height difference | m | 15 |
| Outdoor unit model | — | RZFC13EV2S |
| Liquid refrigerant pipe size | mm/inch/Hun | Ø6.4 (Flare) |
| Outdoor heat exchanger type | — | CAZ Protection (Anti - Corrosion Micro Channel) |
| Gas refrigerant pipe size | mm/inch/Hun | Ø12.7 (Flare) |
| Compressor motor output | W | 1,100 |
| Sound level | dB(A) | 48 |
| Factory refrigerant charge | kg | 0.60 |
| Drain connection size | mm | Ø16 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| System data | ||
| Cooling capacity | kW | 5.3/(2.3~6.0) |
| Seasonal energy efficiency ratio (SEER) | BTU/W.h | 17.07 |
| Power supply | V/Ph/Hz | Supply from Outdoor and Indoor(Indoor) EV2S: 220V / 1 Phase / 50Hz(Outdoor) EV2S: 220V / 1 Phase / 50Hz |
| System model combination | — | FDLF18EV2S/RZFC18EV2S |
| Power input | W | 1,680 |
| Cooling capacity | BTU/hr | 18,000/(7800~20500) |
| Indoor unit | ||
| Airflow rate | cfm | 565 / 494 / 423 |
| Fan speed settings | — | 3Step |
| Air filter | — | Removable/Washable/Mildew proof |
| Sound level | dB(A) | 37 / 33/ 30 |
| Dimensions (H × W × D) | mm | 200 x 900 x 620 |
| Weight | kg | 28 |
| Indoor unit model | — | FDLF18EV2S |
| External static pressure | Pa | Rated 15/(15-38) |
| Drain connection size | mm | VP25 (I.D.∅25 x O.D.∅34) |
| Airflow rate | m3/min | 16/14/12 |
| Outdoor unit | ||
| Dimensions (H × W × D) | mm | 595x845x300 |
| Weight | kg | 34 |
| Compressor type | — | Hermetically sealed swing type |
| Refrigerant | — | R32 |
| Piping length without additional refrigerant | m | 15 |
| Maximum piping length | m | 30 (equivalent length 40 m) |
| Maximum height difference | m | 15 |
| Outdoor unit model | — | RZFC18EV2S |
| Liquid refrigerant pipe size | mm/inch/Hun | Ø6.4 (Flare) |
| Outdoor heat exchanger type | — | CAZ Protection (Anti - Corrosion Micro Channel) |
| Gas refrigerant pipe size | mm/inch/Hun | Ø12.7 (Flare) |
| Compressor motor output | W | 1,100 |
| Sound level | dB(A) | 49 |
| Factory refrigerant charge | kg | 0.60 |
| Drain connection size | mm | Ø16 |
| Specification | Unit | Manufacturer data |
|---|---|---|
| System data | ||
| Cooling capacity | kW | 7.0/(2.6~8.0) |
| Seasonal energy efficiency ratio (SEER) | BTU/W.h | 17.07 |
| Power supply | V/Ph/Hz | Supply from Outdoor and Indoor(Indoor) EV2S: 220V / 1 Phase / 50Hz(Outdoor) EV2S: 220V / 1 Phase / 50Hz |
| System model combination | — | FDLF24EV2S/RZFC24EV2S |
| Power input | W | 2,230 |
| Cooling capacity | BTU/hr | 24,000/(8900~27300) |
| Indoor unit | ||
| Airflow rate | cfm | 706 / 635 / 582 |
| Fan speed settings | — | 3Step |
| Air filter | — | Removable/Washable/Mildew proof |
| Sound level | dB(A) | 40 / 37 / 34 |
| Dimensions (H × W × D) | mm | 200 x 1,100 x 620 |
| Weight | kg | 31 |
| Indoor unit model | — | FDLF24EV2S |
| External static pressure | Pa | Rated 15/(15-38) |
| Drain connection size | mm | VP25 (I.D.∅25 x O.D.∅34) |
| Airflow rate | m3/min | 20/18/16.5 |
| Outdoor unit | ||
| Dimensions (H × W × D) | mm | 595x845x300 |
| Weight | kg | 37 |
| Compressor type | — | Hermetically sealed swing type |
| Refrigerant | — | R32 |
| Piping length without additional refrigerant | m | 10 |
| Maximum piping length | m | 30 (equivalent length 40 m) |
| Maximum height difference | m | 15 |
| Outdoor unit model | — | RZFC24EV2S |
| Liquid refrigerant pipe size | mm/inch/Hun | Ø9.5 (Flare) |
| Outdoor heat exchanger type | — | CAZ Protection (Anti - Corrosion Micro Channel) |
| Gas refrigerant pipe size | mm/inch/Hun | Ø15.9 (Flare) |
| Compressor motor output | W | 1,300 |
| Sound level | dB(A) | 50 |
| Factory refrigerant charge | kg | 0.80 |
| Drain connection size | mm | Ø16 |
Specifications apply to the selected model. Noise and airflow can vary with operating settings. Compare efficiency figures under equivalent test conditions. Matching cooling capacity alone does not establish suitability for replacing an existing unit.
No. That is the unit height. Drainage, insulation, suspension and service access need additional space determined by the installation manual and site conditions.
Calculate the heat load from room size, height, sunlight, occupancy and equipment. AirHub360 can then help check the model, power supply and outdoor-unit location.
AIRHUB360 / LET’S PLAN TOGETHER
Start with ceiling height, available ceiling void, equipment position and airflow direction. Then assess heat load, electrical supply, refrigerant and drain routes, and maintenance access. Our 4-way cassette family includes Round Flow for easier comparison of installation formats. Round Flow distributes air through 360 degrees, rather than just four directions.
LET’S TALK ABOUT YOUR SPACE
Tell us about your space and what you need. The AirHub360 team can help you plan the next step.